Products > Cellometer Auto
Cellometer Auto is a line of simple to use, automated cell counters
designed to improve accuracy, repeatability, and throughput compared
to manual cell counting with a hemacytometer. It uses brightfield
microscopy images to analyze cell samples to determine cell
concentration and trypan blue viability.
Best Suited For:
- Total cell concentration for highly viable cell population
- Live cell concentration and viability using trypan blue
- Cell size measurement
- Identify and count cells based on cell size difference
- Capture and store cell images
|
|
|
1. Pipette 20µL Sample |
2. Insert Slide |
3. Get Data |
The Cellometer Auto T4, a trypan blue viability cell counter, offers unique and superior functionalities and capabilities due to innovative design and sophisticated software.
By using advanced cell counting chamber technology, Cellometer Auto T4 eliminates cross contamination, allows for no maintenance and immediate setup and use. This makes it suitable for occasional use or users with a larger volume of cell samples.
- High quality microscopic cell images for observation of cell morphology and sample quality
- Fast, accurate cell counting: less than 30 seconds for a typical cell line sample
- Declustering ability for clumpy cells
- Cell size histogram
- Review counted cells on screen for data verification
- Direct link to Nexcelom applications support team
- Auto saving for cell counting data and cell images for record keeping
- Ability to store and print data through computer network
- Sample adjustment calculation for the next step in the experiment to eliminate manual data transfer induced errors
Advanced features of Cellometer Auto T4 Include:
- Deep gap counting chamber with innovative counting method for cells or spheres larger than 100 micron
- Option to manually adjust cell count
- Use default cell parameter for simple cell counting
- Import cell types from Nexcelom cell library (250+ cell types)
- Cell type wizard for automatic set up new cell types
- Modify cell size parameters when needed and re-calculate for new results
- Auto sample ID increment for large numbers of samples
- Detailed data for each cell count saved in Excel for comparison between samples
|
Compact, Simple to Use
Cellometer Auto takes up almost no bench space and is incredibly easy to use.
It's pre-configured for hundreds of cell types, and configuring for new cell types is just as easy. Because it works with your PC or laptop, you get a full screen display, easy data input, and the ability to import/export data to a local or network location.
Cellometer also runs on Intel based Macs running Parallels/WinXP. |
| |
|
|
Fast Results
Because it can generate cell counts, size measurements, and concentration calculations in approximately 30 seconds, Cellometer enables you to generate data many times faster than manual counting. |
| |
|
|
Minimal Sample Prep
Disposable Counting Chambers is the only consumable needed to run Cellometer. Only 20uL of sample is required, and the chambers load in seconds, and when done can be disposed, eliminating the need for cover slips and washing between samples. |
| |
|
|
Trypan Blue Viability
Trypan Blue treated cells are automatically counted as live or dead, and the percentage viability is automatically calculated. Live counted cells are indicated by a green circle on-screen, and Dead counted cells by a red-circle. |
| |
|
|
On-screen Imaging
No two cells are the same, which is why live cell morphology can be immediately viewed on-screen, and counted cells are indicated on-screen for further analysis. The counting results are indicated for each cell and images can be saved or exported for a secure record of all of your cell counts. |
| |
|
|
Cell Size Measurement
Unlike manual counting, Cellometer measures both individual and mean cell sizes, and can generate size distribution histograms for all counted cells. Multiple histograms can be overlaid for determining changes in cell sizes over time. |
| |
|
|
Advanced Imaging Technology
Microscope quality optics and advanced vision software ensure that even the most challenging samples can be counted. This includes counting specific cells in a heterogeneous sample, declustering cell clumps (such as MCF7), counting irregular shaped cells, and excluding cellular debris. |
| |
|
|
Save & Export Data, Images, and Graphs
Keeping records of your research is critical. With the click of a button, Cellometer instantly saves counting results, cell images, graphs, and data to a clipboard, local or network location. |
| |
|
|
Local, World Class Support
Nexcelom support is provided from of our Boston area headquarters. Our support team includes PhD's and experts in cell biology, digital imaging systems, and software, and are available via phone or email to help setup, configure and use your Cellometer automated cell counter. We also offer online/onsite training & web based remote instrument control to assist with your cell counting applications. |
|
Cellometer’s automatic cell counting principle is based on imaging cytometry. Cells in suspension are spread into a thin layer of liquid when loaded in a Disposable Counting Chamber. The instrument is connected to a computer via USB 2.0 connection and acquires cell images from multiple locations of the counting chamber. The software then analyzes these images and determines cell concentration, trypan viability and cell size. Results & cell images are displayed on-screen and in approximately 30 seconds.
|
 |
1. Load Counting Chamber
Simply pipette 20uL into one side of a disposable counting chamber. It's nearly impossible to overload or underload, and capillary action automatically spreads your sample into a monolayer. Each slide holds two samples and feature a large, white writing surface for sample identification.
|
| |
|
 |
2. Insert Silde
The counting chamber is loaded into a slot on the front of the instrument. Click 'Display Image'', then 'Count' to begin counting. |
| |
|
 |
3. Get Data
Less than 30 seconds later, counted images are displayed on-screen, as well as live cell count, dead cell count, concentration, and mean size. Cell size histograms and other data can be instantly displayed, and all data & images can then be saved, or exported. |
| |
|
Other Features |
 |
Configuring for Different Cell Types
Cellometer features more than 250 pre-programmed cell type parameters. New cell types are easily added via a New Cell Type Wizard or manual configuration. Configuring or fine tuning Cellometer for your specific assay needs is simple and straightforward, and our Support Team is always available to assist. |
| |
|
 |
Declustering
Cellometer's advanced imaging can locate and accurately count cells in clumps or clusters. This feature is adjustable for your particular needs, and can also be turned off completely to count the number of clumps in a sample. |
| |
|
 |
Exclude Cellular Debris
Because Cellometer recognizes cells based on size, brightness, and morphology- cellular debris can be excluded from counting results ensuring accurate results. |
| |
|
 |
Heterogeneous Cell Samples
Minimum and maximum cell size parameters can be set to only count specific cells in a heterogeneous sample. This is deal for counting dendritic cells cultured from PBMC, or counting PBMCs amongst platelets. |
| |
|
 |
Irregular Cell Shapes
Cellometer can recognize and count irregular shaped cells by adjusting the roundness cell setting. Ideal for counting RD cells or activated T-cells. |
| |
|
 |
Changes in Cell Diameter
Because Cellometer generates individual cell size measurements, multiple samples can be overlaid on one histogram, enabling analysis of change in cell diameter over time, such as when counting SF9 or SF21 cells. Saved images can be viewed and counted later to analyze changes in morphology over time. |
 |
Cellometer comes pre-configured for more than 250 cell types. To view example images and for a complete list of supported cells click here. |

Lymphocyte/Lymphocyte Counted |
Cellometer Auto T4 Plus is routinely used for counting cells in immunology research, such as lymphocytes, thymocytes, PBMC, B-cells, & T-cells. Cellometer's ability to count specific cells based on size, enables PBMCs to be accurately counted from platelet background... learn more |

CHO/HEK293 |
Cellometer Auto T4 Plus is ideally suited for counting cancer cell lines. For example cell types and images, click here.
|

Uninfected/Infected |
Cellometer Auto T4 Plus can be used to count cell concentration, viability and size distribution of insect cells, such as SF9 & SF21 to monitor cell size changes before and after infection... learn more |

DC Matured from PBMC |
Samples containing cells of various size, such as Fresh Human PBMC among platelets, and dendritic cells cultured from PBMC can be accurately counted with Cellometer Auto T4 Plus.. learn more. |

Yeast/Yeast-counted |
Cellometer Auto M10 features high magnification optics and provides sufficient resolution to count and decluster smaller cells such as Yeast or Algae.. learn more. |

Fresh human platelets |
Platelets
Cellometer Auto M10's high magnification also offers sufficient resolution to count Platelets… learn more.
|
| |
Cellometer Auto T4 Plus: |
Cellometer Auto M10: |
Includes |
Auto T4 Plus instrument, software, USB 2.0 connection cable, power supply & phone/online applications support during setup |
Auto M10 instrument, software, USB 2.0 connection cable, power supply & phone/online applications support during setup |
Cell Sizes |
Most Cells 5-60 microns
|
2-12 microns
Yeast, Platelets, & Algae |
Concentration Range: |
2.5x105/ml - 1.0x107/ml |
5.0x105/ml - 5.0x107/ml |
Performance Comparison data: |
Total Count vs. Hemacytometer
Viability vs. Hemacytometer
PBMC Dilution Series
L929 Dilution series |
Contact Us for more information. |
Weight:
Dimensions:
Power Input: |
10 lbs
W5.0" x D5.0" x H13.0"
100-240V AC, 50-60Hz, 0.5A |
PC or Laptop requirements: |
|
|
|