Automatic cell viability counter with dual fluorescence
Cellometer Auto 2000 All-In-One Design
Inovative and Intuative Software

All-In-One Design, Small Foot Print

The Cellometer Auto 2000 offers many features including:
  • 20 µL sample volume
  • Viability by AO/PI, PI or trypan blue
  • Dual fluorescence plus brightfield imaging
  • Disposable counting chamber
Request More Information
PBMC

PBMC

Spleenocytes

Splenocytes

Cell Lines

Cell Lines

PI Viability

PI Viability

Stem Cells

Stem Cells

Cellometer Auto 2000 Standard Assays

Immune Cells with Low RBC - Nucleated immune cells after isolation in samples with some red blood cells stained with AO/PI. PBMC after Ficoll separation, Splenocyte without lysing RBC, lymphocyte, bone marrow, cord blood and lung lavage.
Immune Cells with High RBC - Nucleated cells in samples with large amount of red blood cells stained with AO/PI. Whole blood, cord blood and bone marrow.
Stem cells, primary cells - Stem cells, primary cells from dissociated tissues with debris stained with AO/PI. Learn more »
Cell Line - Cell lines or cultured primary cells without debris stained with PI or trypan blue. Learn more »
Cell Line Total Concentration - Cell lines or cultured primary cells without debris at viability greater than 98%. Learn more »
Low Cell Concentration - Isolated primary cells or cell lines stained with AO with concentration between (0.25 -2.5) x105 cells / ml. Learn more »
User Defined - Produce customized assay settings
Quantitative Fluorescence Intensity Data

Concentration Dynamic Range and Repeatability

Data shown depicts the dynamic range for cell concentration measurements on Cellometer Auto 2000. The concentration can be measured from 1 x 105 - 1 x 107 cells / mL without further dilution.

The %CV at each concentration was below 10%. This data set was taken on a concentration series of primary mouse splenocytes.

Innovative & Intuitive System - All on a Touch Screen

The Cellometer Auto 2000 offers standard assays for live/dead cell concentration and viability with the option to modify included assays. Other benefits include:
  • Instant staining and counting
  • No lysing of RBC needed
  • Eliminates variation caused by debris
  • No washing biohazard
Results in less than 60 seconds

Fast

From loading the counting chamber to viewing cell morphology and counting, Cellometer Auto 2000 typically produces the cell analysis results in less than 60 seconds.

Cellometer Auto 2000 and Related Products

Catalog # Product Name Quantity
Cellometer Auto 2000 Automatic Cell Viability Counter system with dual fluorescence, including 75 slides for 150 counts. 1 Unit
CHT4-SD100-014 Disposable Counting Chamber 1 Case
CS2-0106-5ML AO/PI Fluorescent Stain Each
CS1-0108-5ML AO Fluorescent Stain Each
CS1-0109-5ML PI Fluorescent Stain Each

Cellometer Auto 2000 Cellometer Auto 2000 Resources